Find great deals for Hörmann Universaladapterplatine UAP 1. Shop with confidence on eBay!. For Hörmann door, Type: SupraMatic, Rotamatic / P / PL from year 09/ and LineaMatic built from 10/ – About for direction selection (up / stop / close). For inputs to Hormann: does it mean that I have to run 6 wires for this section from Loxone to Hormann? Or is it possible to reuse the wire for

Author: Turr Faerisar
Country: Papua New Guinea
Language: English (Spanish)
Genre: Literature
Published (Last): 7 April 2014
Pages: 131
PDF File Size: 11.75 Mb
ePub File Size: 10.38 Mb
ISBN: 943-8-48295-875-1
Downloads: 44845
Price: Free* [*Free Regsitration Required]
Uploader: Zolozshura

As you can see the only status bit set, is from the second byte and means reversing according to the patent which makes no sense to me. This question came from our site for electronics and electrical engineering professionals, students, and enthusiasts.

Reverse engeneering the Hörmann UAP1 protocoll

I see one for your supramatic seems a bit over complicated for a Garage Door – however reading the instructions for the ventilation position You might find what you need here. Post as a guest Name.

It decrements this address and scans the entire bus. Sign up using Email and Password. For that to work I needed to buy a UAP universal adapter, meant for uses like these and connect it to horjann Loxone miniserver.

After having discussed that issue with my Italian friend he was able to figure out the polynom 0x07 as well as the initial value 0xF3 for the CRC algorithm. Usa a UAP1, a small extension box to have better control over the motor and get kap1 feedback signals.

  KRUGMAN POP INTERNATIONALISM PDF

I might misinterprete some of them at this point: Quiescent current circuit open Bit 4: I expected a rather simple protocoll where no comunication happens until the UAP1 gets triggered by a switch, but I was more than wrong.

Bottom side of the circuit board: Exactly what I want to have: Burglar alarm As you can see the only status bit set, is from the second byte and means reversing according to the patent which makes no sense to me. Here’s what I got using the USB converter with the door closed idling: I searched the internet for information about the bus, jap1 little to nothing can be found about it. Dominik Hadl 51 4.

By clicking “Post Your Answer”, you acknowledge that you have read our updated terms of serviceprivacy policy and cookie policyand that your continued use of the website is subject to these policies. Whith that one I can hkrmann when the UAP1 is sending and when it is receiving!

It seems that this must happen when hormqnn UAP1 is connected to the motor. I’ll try to extend this artcle or write a followup in the future. Not much to see here, just that all pins of the 6-pin RJ12 sockets are directly conected to each other. Hormann garage door opener automation hormamn Loxone Ask Question.

The only things I get from what is stated is that if you press to open – you press the button again to stop it not a true move up move down motion.

Hörmann Universaladapterplatine UAP 1

That tells me that it appears your UAP will not allow for the individual movements that you are looking to achieve. Connect potential free contacts directly to the motor. Email Required, but never shown. Could it be that you 0.

  INSTANT RADIOSITY KELLER PDF

I hoped to find the signals there as well but it turned out that is not the case. Drives at least the three relais, maybe more. To control the door via a home automation system you have several options: Hi Ken, as you say in the beginning of the reply the UAP enables me to “open the garage door” and “close the garage door” which is what I want to achieve same as what the person who wrote the guide I linked to achievedsorry if I didn’t explain properly.

Broadcast status From the beginning the master sends a broadcast status message. The slave responds to a status request by the master.

low voltage – Hormann garage door opener automation with Loxone – Home Improvement Stack Exchange

Furthermore I’ve only see this reply all the time. Option relay on Bit 3: That being said you might be able to program a button to activate open when pressed hlrmann to also activate the same function on release.

That means you have just very basic control over the motor because you can’t ua1p up and down command but just a go command as you can with the radio controls. In my case it starts at address 0x8D which is in decimal.